Arghode, Vaibhav K.
Air Flow Management in Raised Floor Data Centers [electronic resource] / by Vaibhav K. Arghode, Yogendra Joshi. - XX, 72 p. 39 illus., 3 illus. in color. online resource. - SpringerBriefs in Applied Sciences and Technology, 2191-530X . - SpringerBriefs in Applied Sciences and Technology, .
1. Introduction -- 2. Metrology Tools -- 3. Cooling Air Delivery Through Perforated Tiles -- 4. Cold Aisle Containment -- 5. Other Air Delivery Schemes.
The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.
9783319258928
10.1007/978-3-319-25892-8 doi
Engineering.
Computer hardware.
Thermodynamics.
Heat engineering.
Heat transfer.
Mass transfer.
Facility management.
Engineering.
Facility Management.
Energy Efficiency.
Engineering Thermodynamics, Heat and Mass Transfer.
Computer Hardware.
TH1-9745
658.2
Air Flow Management in Raised Floor Data Centers [electronic resource] / by Vaibhav K. Arghode, Yogendra Joshi. - XX, 72 p. 39 illus., 3 illus. in color. online resource. - SpringerBriefs in Applied Sciences and Technology, 2191-530X . - SpringerBriefs in Applied Sciences and Technology, .
1. Introduction -- 2. Metrology Tools -- 3. Cooling Air Delivery Through Perforated Tiles -- 4. Cold Aisle Containment -- 5. Other Air Delivery Schemes.
The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.
9783319258928
10.1007/978-3-319-25892-8 doi
Engineering.
Computer hardware.
Thermodynamics.
Heat engineering.
Heat transfer.
Mass transfer.
Facility management.
Engineering.
Facility Management.
Energy Efficiency.
Engineering Thermodynamics, Heat and Mass Transfer.
Computer Hardware.
TH1-9745
658.2