Best Practices for Commercial Roof-Mounted Photovoltaic System Installation (Record no. 57281)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03281nam a22006015i 4500 |
001 - CONTROL NUMBER | |
control field | 978-1-4939-2883-5 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20200421112219.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 150522s2015 xxu| s |||| 0|eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781493928835 |
-- | 978-1-4939-2883-5 |
082 04 - CLASSIFICATION NUMBER | |
Call Number | 690 |
100 1# - AUTHOR NAME | |
Author | Wills, Rosalie. |
245 10 - TITLE STATEMENT | |
Title | Best Practices for Commercial Roof-Mounted Photovoltaic System Installation |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | XIV, 76 p. 14 illus. |
490 1# - SERIES STATEMENT | |
Series statement | SpringerBriefs in Fire, |
505 0# - FORMATTED CONTENTS NOTE | |
Remark 2 | Introduction -- Structural Loading -- Wind Loads -- Hail -- Snow -- Debris Accumulation -- Seismic -- Fire Hazards -- Electrical Hazards Associated with Fire Fighter Operations -- Weather-related Maintenance Considerations -- Compilation of Best Practices -- Hazard Gap Analysis. |
520 ## - SUMMARY, ETC. | |
Summary, etc | This SpringerBrief presents information on a wide variety of hazards and the damage potential caused by installation of a photovoltaic (PV) system. The current installation practices for PV systems on roofs create electrical, fire, structural, and weather-related hazards that do not comply to current codes, standards and guidance documents. Potential dangers include structural loading, wind loads, hail, snow, debris accumulation, seismic hazards, firefighting hazards, and electrical hazards. Despite the increased popularity of PV systems after the environmental movement, research shows that the costs of installing PV systems outweigh the benefits. Hazards of PV systems on roofs have caused several incidents in the United States; the most notable in Bakersfield, California, and Mount Holly, North Carolina. Designed for fire engineers and professionals, Best Practices for Commercial Roof-Mounted Photovoltaic System Installation offers recommendations to set up PV systems safely and sustainably. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
General subdivision | Design and construction. |
700 1# - AUTHOR 2 | |
Author 2 | Milke, James A. |
700 1# - AUTHOR 2 | |
Author 2 | Royle, Sara. |
700 1# - AUTHOR 2 | |
Author 2 | Steranka, Kristin. |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | http://dx.doi.org/10.1007/978-1-4939-2883-5 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | eBooks |
264 #1 - | |
-- | New York, NY : |
-- | Springer New York : |
-- | Imprint: Springer, |
-- | 2015. |
336 ## - | |
-- | text |
-- | txt |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | c |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | cr |
-- | rdacarrier |
347 ## - | |
-- | text file |
-- | |
-- | rda |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Engineering. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Structural mechanics. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Quality control. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Reliability. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Industrial safety. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Buildings |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Building. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Construction. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Engineering, Architectural. |
650 14 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Engineering. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Building Construction. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Structural Mechanics. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Quality Control, Reliability, Safety and Risk. |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE | |
-- | 2193-6595 |
912 ## - | |
-- | ZDB-2-SCS |
No items available.