High voltage protection for telecommunications / (Record no. 59799)

000 -LEADER
fixed length control field 05585nam a2201081 i 4500
001 - CONTROL NUMBER
control field 6047608
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20200421114237.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151221s2011 nju ob 001 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
ISBN 9781118127018
-- ebook
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
-- print
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
-- electronic
082 04 - CLASSIFICATION NUMBER
Call Number 621.38215
100 1# - AUTHOR NAME
Author Blume, Steven Warren,
245 10 - TITLE STATEMENT
Title High voltage protection for telecommunications /
300 ## - PHYSICAL DESCRIPTION
Number of Pages 1 PDF (256 pages).
490 1# - SERIES STATEMENT
Series statement IEEE Press series on power engineering ;
500 ## - GENERAL NOTE
Remark 1 In Wiley online library
505 0# - FORMATTED CONTENTS NOTE
Remark 2 Preface ix -- Acknowledgments xiii -- About the Author xv -- 1 Overview of High Voltage Protection for Telecommunications 1 -- Basic Purpose and Applications, 2 -- The HV Protection Challenge, 3 -- HV Isolation Standards, 7 -- 2 Electric Power System Fundamentals 11 -- Power Terminology for Telecommunications, 12 -- Electric Power System Overview, 21 -- AC Voltage Generation, 23 -- Substation Equipment, 31 -- Transmission Lines, 44 -- Distribution Lines, 45 -- System Protection Equipment and Concepts, 47 -- 3 Ground Potential Rise (GPR) and Zone of Influence 63 -- Introduction to Ground Potential Rise (GPR), 64 -- GPR, 65 -- GPR Locations, 66 -- Factors Affecting GPR, 71 -- Calculation of GPR, 86 -- ZOI, 88 -- Earth Resistivity, 91 -- GPR and ZOI Calculation Methods, 95 -- Lightning Faults, 107 -- Electromagnetic Induction under Fault Conditions, 109 -- Total Electrical Cable Stress, 118 -- The Role of Protection Engineers, 119 -- 4 Critical Telecommunications Circuits in HV Environments 121 -- General, 122 -- Service Performance Objectives (SPOs), 122 -- North America Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) Standards, 125 -- Protective Relaying Schemes that Require Class A Circuits, 126 -- Power Applications that Require Class B Circuits, 131 -- Power Communication Service Types, 136 -- Smart Grid and Cyber Security, 139 -- 5 High Voltage Protection Equipment 143 -- General, 144 -- Basic Shunt Protection, 144 -- Levels of Protection, 149 -- Special Consideration for Nearby Facilities, 166 -- 6 Level III HV Protection Equipment, Installation, and Testing 167 -- General, 168 -- Level III Copper HVI Components, 169 -- Copper HVI System Design, 181 -- Copper HVI Installation Examples, 191 -- Copper HVI System Initial Testing, 195 -- Copper HVI Maintenance and Inspection, 197 -- Fiber HVI Systems Installation, 199 -- Fiber HVI Installation Examples, 202 -- Wireless Sites on Electrical Power Towers, 205 -- Protection at Non-Power Company Locations, 211.
505 8# - FORMATTED CONTENTS NOTE
Remark 2 7 Personnel Safety Working with HV Protection Equipment 217 -- Electrical Safety, 218 -- Electrical Protection Priorities, 218 -- Touch and Step Potentials, 219 -- Glossary 227 -- Appendix: Service Request Form 231 -- Bibliography 235 -- Index 237.
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
General subdivision Equipment and supplies
-- Protection.
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
General subdivision Protection.
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
General subdivision Prevention.
856 42 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://ieeexplore.ieee.org/xpl/bkabstractplus.jsp?bkn=6047608
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type eBooks
264 #1 -
-- Oxford :
-- Wiley-Blackwell,
-- 2011.
264 #2 -
-- [Piscataqay, New Jersey] :
-- IEEE Xplore,
-- [2011]
336 ## -
-- text
-- rdacontent
337 ## -
-- electronic
-- isbdmedia
338 ## -
-- online resource
-- rdacarrier
588 ## -
-- Description based on PDF viewed 12/21/2015.
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
-- Telecommunication
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
-- Telecommunication lines
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
-- Transients (Electricity)
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
-- Overvoltage
695 ## -
-- Advertising
695 ## -
-- Batteries
695 ## -
-- Bibliographies
695 ## -
-- Cable insulation
695 ## -
-- Cable shielding
695 ## -
-- Carbon
695 ## -
-- Circuit faults
695 ## -
-- Communication cables
695 ## -
-- Companies
695 ## -
-- Conductors
695 ## -
-- Copper
695 ## -
-- Earth
695 ## -
-- Electric potential
695 ## -
-- Electron tubes
695 ## -
-- Facsimile
695 ## -
-- Fault currents
695 ## -
-- Ground penetrating radar
695 ## -
-- Grounding
695 ## -
-- IEEE Potentials
695 ## -
-- IEEE Press
695 ## -
-- Impedance
695 ## -
-- Indexes
695 ## -
-- Integrated circuit reliability
695 ## -
-- Lightning
695 ## -
-- Marketing and sales
695 ## -
-- Optical fiber communication
695 ## -
-- Optical sensors
695 ## -
-- Personnel
695 ## -
-- Power cables
695 ## -
-- Power system reliability
695 ## -
-- Power systems
695 ## -
-- Power transformer insulation
695 ## -
-- Relays
695 ## -
-- Resistance
695 ## -
-- Rubber
695 ## -
-- Safety
695 ## -
-- Shunt (electrical)
695 ## -
-- Soil
695 ## -
-- Standards
695 ## -
-- Substations
695 ## -
-- Telecommunication services
695 ## -
-- Telecommunications
695 ## -
-- Transient analysis
695 ## -
-- Warranties
695 ## -
-- Wireless communication

No items available.