Wireless Power Transfer and Data Communication for Neural Implants (Record no. 78992)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03398nam a22005535i 4500 |
001 - CONTROL NUMBER | |
control field | 978-3-319-49337-4 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20220801220832.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170102s2017 sz | s |||| 0|eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9783319493374 |
-- | 978-3-319-49337-4 |
082 04 - CLASSIFICATION NUMBER | |
Call Number | 621.3815 |
100 1# - AUTHOR NAME | |
Author | Yilmaz, Gürkan. |
245 10 - TITLE STATEMENT | |
Title | Wireless Power Transfer and Data Communication for Neural Implants |
Sub Title | Case Study: Epilepsy Monitoring / |
250 ## - EDITION STATEMENT | |
Edition statement | 1st ed. 2017. |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | XII, 110 p. 65 illus., 60 illus. in color. |
490 1# - SERIES STATEMENT | |
Series statement | Analog Circuits and Signal Processing, |
505 0# - FORMATTED CONTENTS NOTE | |
Remark 2 | Introduction -- System Overview -- Wireless Power Transfer -- Wireless Data Communication -- Packaging of the Implant -- System Level Experiments and Results -- Conclusion. |
520 ## - SUMMARY, ETC. | |
Summary, etc | This book presents new circuits and systems for implantable biomedical applications targeting neural recording. The authors describe a system design adapted to conform to the requirements of an epilepsy monitoring system. Throughout the book, these requirements are reflected in terms of implant size, power consumption, and data rate. In addition to theoretical background which explains the relevant technical challenges, the authors provide practical, step-by-step solutions to these problems. Readers will gain understanding of the numerical values in such a system, enabling projections for feasibility of new projects. Provides complete, system-level perspective for implantable batteryless biomedical system; Extends design example to implementation and long term in-vitro validation; Discusses system design concerns regarding wireless power transmission and wireless data communication, particularly for systems in which both are performed on the same channel/frequency; Presents fully-integrated, implantable system and hermetically sealed packaging. |
700 1# - AUTHOR 2 | |
Author 2 | Dehollain, Catherine. |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | https://doi.org/10.1007/978-3-319-49337-4 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | eBooks |
264 #1 - | |
-- | Cham : |
-- | Springer International Publishing : |
-- | Imprint: Springer, |
-- | 2017. |
336 ## - | |
-- | text |
-- | txt |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | c |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | cr |
-- | rdacarrier |
347 ## - | |
-- | text file |
-- | |
-- | rda |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronic circuits. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biomedical engineering. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronics. |
650 14 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronic Circuits and Systems. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biomedical Engineering and Bioengineering. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronics and Microelectronics, Instrumentation. |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE | |
-- | 2197-1854 |
912 ## - | |
-- | ZDB-2-ENG |
912 ## - | |
-- | ZDB-2-SXE |
No items available.