000 03356nam a22005295i 4500
001 978-3-319-07010-0
003 DE-He213
005 20200421112546.0
007 cr nn 008mamaa
008 140603s2014 gw | s |||| 0|eng d
020 _a9783319070100
_9978-3-319-07010-0
024 7 _a10.1007/978-3-319-07010-0
_2doi
050 4 _aTK7800-8360
050 4 _aTK7874-7874.9
072 7 _aTJF
_2bicssc
072 7 _aTEC008000
_2bisacsh
072 7 _aTEC008070
_2bisacsh
082 0 4 _a621.381
_223
100 1 _aOlszowiec, Piotr.
_eauthor.
245 1 0 _aInsulation Measurement and Supervision in Live AC and DC Unearthed Systems
_h[electronic resource] /
_cby Piotr Olszowiec.
250 _a2nd ed. 2014.
264 1 _aCham :
_bSpringer International Publishing :
_bImprint: Springer,
_c2014.
300 _aXI, 180 p. 132 illus.
_bonline resource.
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
490 1 _aLecture Notes in Electrical Engineering,
_x1876-1100 ;
_v314
520 _aLow voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use are high reliability and numerous advantages offered by isolating them against ground. Insulation level is a decisive factor for networks operational reliability and safety. Insufficient insulation-to-ground resistance can cause various disturbances. Though ground faults in IT systems do not make networks operation impossible, they may cause severe problems with their safe functioning. In this book the most important issues concerning normal operation and ground fault phenomena are described in concise form. Numerous methods of insulation resistance and capacitance measurement in live circuits are presented. Important other procedures of  these parameters determination based on measurement and calculation are explained and reviews of selected insulation resistance measurement devices as well as earth fault locating systems are included. This book is addressed to electrical engineers, technicians and students and may also serve as an academic handbook. The extended second edition includes several innovative methods of insulation parameters determination as well as more detailed explanations of procedures and issues. Furthermore new important problems e.g. indirect methods of insulation resistance determination and insulation resistance monitoring in networks with frequency converters are addressed as well as examples of practical applications.
650 0 _aEngineering.
650 0 _aPhysics.
650 0 _aElectronics.
650 0 _aMicroelectronics.
650 0 _aPower electronics.
650 1 4 _aEngineering.
650 2 4 _aElectronics and Microelectronics, Instrumentation.
650 2 4 _aPower Electronics, Electrical Machines and Networks.
650 2 4 _aPhysics, general.
710 2 _aSpringerLink (Online service)
773 0 _tSpringer eBooks
776 0 8 _iPrinted edition:
_z9783319070094
830 0 _aLecture Notes in Electrical Engineering,
_x1876-1100 ;
_v314
856 4 0 _uhttp://dx.doi.org/10.1007/978-3-319-07010-0
912 _aZDB-2-ENG
942 _cEBK
999 _c58605
_d58605