000 | 04192nam a2200769 i 4500 | ||
---|---|---|---|
001 | 5444115 | ||
003 | IEEE | ||
005 | 20220712205739.0 | ||
006 | m o d | ||
007 | cr |n||||||||| | ||
008 | 151221s2010 nju ob 001 eng d | ||
010 | _z 2005299697 (print) | ||
020 |
_a9780471718741 _qelectronic |
||
020 | _a0471718742 | ||
020 |
_z9780471679097 _qprint |
||
020 |
_z1601195656 _qelectronic |
||
020 |
_z0471679097 _qpaper |
||
020 |
_z9781601195654 _qelectronic |
||
024 | 7 |
_a10.1109/9780471718741 _2doi |
|
035 | _a(CaBNVSL)mat05444115 | ||
035 | _a(IDAMS)0b0000648122294c | ||
040 |
_aCaBNVSL _beng _erda _cCaBNVSL _dCaBNVSL |
||
050 | 4 |
_aTK3255 _b.A74 2005eb |
|
082 | 0 | 4 |
_a621.319/34 _222 |
082 | 0 | 4 |
_a621.31934 _222 |
100 | 1 |
_aAnders, George J., _eauthor. _927447 |
|
245 | 1 | 0 |
_aRating of electric power cables in unfavorable thermal environment / _cGeorge J. Anders. |
264 | 1 |
_aHoboken, New Jersey : _bWiley, _cc2005. |
|
264 | 2 |
_a[Piscataqay, New Jersey] : _bIEEE Xplore, _c[2010] |
|
300 | _a1 PDF (xiv, 326 pages). | ||
336 |
_atext _2rdacontent |
||
337 |
_aelectronic _2isbdmedia |
||
338 |
_aonline resource _2rdacarrier |
||
490 | 1 |
_aIEEE Press series on power engineering ; _v19 |
|
504 | _aIncludes bibliographical references and index. | ||
505 | 0 | _a1. Review of power cable standard rating methods. -- 2. Ampacity reduction factors for cables crossing thermally unfavorable regions. -- 3. Cable crossings - derating considerations. -- 4. Application of thermal backfills for cables crossing unfavorable thermal environments. -- 5. Special considerations for real-time rating analysis and deeply buried cables. -- 6. Installations involving multiple cables in air. -- 7. Rating of pipe-type cables with slow circulation of dielectric fluid. -- Appendix A: Computations of the mean moisture content in media surrounding underground power cables. -- Appendix B: Estimation of backfill thermal resistivity. -- Appendix C: Equations for dielectric fluid parameters. | |
506 | 1 | _aRestricted to subscribers or individual electronic text purchasers. | |
520 | _aRating of Electric Power Cables in Unfavorable Thermal Environment is the first text to provide you with the computational tools and techniques needed to successfully design and install power cables in areas affected by such factors as outside heat sources, ground moisture, or impediments to heat dissipation. After thoroughly reviewing standard rating models, the author discusses several new techniques designed to improve cable ampacity, as well as new computational techniques for analysis of cyclic loads. To facilitate computational tasks he utilizes six representational model cables throughout the book, including transmission-class, high-voltage, distribution, and bundled types. End-of-chapter summaries, liberal numerical examples, and practical, real world applications make this text a valuable resource for making better design and operation decisions. | ||
530 | _aAlso available in print. | ||
538 | _aMode of access: World Wide Web | ||
588 | _aDescription based on PDF viewed 12/21/2015. | ||
650 | 0 |
_aPowerline ampacity. _927448 |
|
650 | 0 |
_aElectric currents _xMathematical models. _921166 |
|
650 | 0 |
_aElectric cables _xThermal properties. _927449 |
|
655 | 0 |
_aElectronic books. _93294 |
|
695 | _aArgon | ||
695 | _aArtificial intelligence | ||
695 | _aCoatings | ||
695 | _aConductors | ||
695 | _aDielectric constant | ||
695 | _aEquations | ||
695 | _aFires | ||
695 | _aFluids | ||
695 | _aHeating | ||
695 | _aIndexes | ||
695 | _aPower cables | ||
695 | _aTemperature | ||
695 | _aVentilation | ||
710 | 2 |
_aIEEE Xplore (Online Service), _edistributor. _927450 |
|
710 | 2 |
_aJohn Wiley & Sons, _epublisher. _96902 |
|
710 | 2 |
_aInstitute of Electrical and Electronics Engineers. _99191 |
|
710 | 2 |
_aKnovel (Firm) _927261 |
|
776 | 0 | 8 |
_iPrint version: _z9780471679097 |
830 | 0 |
_aIEEE Press series on power engineering ; _v19 _97125 |
|
856 | 4 | 2 |
_3Abstract with links to resource _uhttps://ieeexplore.ieee.org/xpl/bkabstractplus.jsp?bkn=5444115 |
942 | _cEBK | ||
999 |
_c74067 _d74067 |